Customization: | Available |
---|---|
Output Power: | >1000W |
Nature of Source Flow: | Active Inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
On grid wind turbine controller | SHJ-10K380 | SHJ-20K380 | SHJ-30K380 | |||
Wind turbine input | ||||||
Power | 10KW | 20KW | 30KW | |||
Max. Control power / current | 20KW/40A | 40KW/80A | 60KW/120A | |||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | |||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | ||
DC | 0-900V | 0-900V | 0-900V | |||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | ||
Set range | 530-560V | 530-560V | 530-560V | |||
Braking current (DC) | Default | 30A | 60A | 90A | ||
Set range | 0-30A | 0-60A | 0-90A | |||
Braking time | Default | 10-20 min | ||||
Set range | 0-5000 min | |||||
* Generator overspeed control | Default | >300 rpm/min | ||||
Set range | 0-1000 rpm/min | |||||
* Over wind speed control | Default | 14 m/s | ||||
Set range | 0-45 m/s | |||||
Manual control | Manual brake, *remote control brake (with communication function) | |||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
|||||
* PV. Input | ||||||
Rated power (increased) | 5KWp | 5KWp | 5KWp | |||
Working voltage (DC) | 550V / 660V | 550V / 660V | 550V / 660V | |||
DC output parameters | ||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | |||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | ||
Set range | 510-540V | 510-540V | 510-540V | |||
Constant current (DC) | Default | 24A | 48A | 72A | ||
Set range | 0-24A | 0-48A | 0-72A | |||
On grid wind turbine inverter | SHJ-10KTL | SHJ-20KTL | SHJ-30KTL | |||
Rated output power (AC) | 10KW | 20KW | 30KW | |||
Max. Output power (AC) | 11KW | 22KW | 33KW | |||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | |||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | |||
Max. Input current (DC) | 2.4A | 44.9A | 67.3A | |||
Rated current | 20.4A | 40.8A | 61.2A | |||
THD Current harmonic | <3%(at rated power) | |||||
Power factor | >0.99 | |||||
Max. efficiency | 98% | |||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | |||||
Allowable grid frequency range | 50Hz/60Hz±10% | |||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | |||||
Restart time after power failure | 2min(Adjustable) | |||||
General parameters | ||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | |||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
|||||
Display | Touch screen, LCD | |||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | |||||
Protection level | IP20(Indoor)IP65 (Outdoors) | |||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | |||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | |||||
Noise (1m) | <40dB | |||||
Refrigeration mode | Forced air cooling | |||||
Controller size / weight | 400*230*550mm 23kg | 500*230*620mm 35kg | 500*230*620mm 38kg | |||
Dump load size / weight | 690*450*530mm 36kg | 980*880*540mm 70kg | 980*880*540mm 70kg | |||
Inverter size / weight | 690*275*770mm 42kg | 690*275*770mm 58kg | 690*275*770mm 65kg | |||