Customization: | Available |
---|---|
Output Power: | >1000W |
Nature of Source Flow: | Passive inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SHJ-NBQ50K-S220 | SHJ-NBQ50K-S380 | |
DC input |
Input rated voltage | 220 VDC | 380 VDC |
Input rated current | 252.5 A | 146 A | |
Input DC voltage allowing range | 180-280 VDC | 350-500VDC | |
AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |
Input rated current | 455A / 417A / 227A /208A | ||
Bypass transfer time | ≤100 ms (4ms optional) | ||
AC output | Rated capacity | 50KVA | |
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||
Output rated current | 455A / 417A / 227A / 208A | ||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Wave | Pure sine wave (Isolation transformer) | ||
THD. | ≤3%(Linear load) | ||
Overload capacity | 120%,10 minutes | ||
Overcurrent capacity | 200%,10 seconds | ||
Overload capacity | 120%,3 minutes,150%,10 second | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | >92% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10ºC~+50ºC | ||
Humidity | 0~90%, No condensation | ||
Altitude | <2000m Higher than 2000m rated power should be reduced |
||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
Equipped With Copper Transformer | Yes | ||
Solar Charger | Optional | ||
AC Charger | Optional | ||
Generator Port | Optional | ||
Size | 660*1300*1600 mm | ||
Weight | 450 kg |
Model | SHJ-NBQ100K-S220 | SHJ-NBQ100K-S380 | |
DC input |
Input rated voltage | 220 VDC | 380 VDC |
Input rated current | 505 A | 292.3A | |
Input DC voltage allowing range | 180-280 VDC | 320-500VDC | |
AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |
Input rated current | 909A / 833A / 455A /417A | ||
Bypass transfer time | ≤100 ms (4ms optional) | ||
AC output | Rated capacity | 100KVA | |
Output rated voltage and frequency | 110VAC / 120VAC / 220VAC / 240VAC,50Hz / 60Hz | ||
Output rated current | 909A / 833A / 455A /417A | ||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||
Wave | Pure sine wave (Isolation transformer) | ||
THD. | ≤3%(Linear load) | ||
Power factor (PF) | 0.8 | ||
Overload capacity | 120%,10 minutes | ||
Overcurrent capacity | 200%,10 seconds | ||
Crest factor (CF) | 3:1 | ||
Inverter efficiency | >94% | ||
Working Environment | Dielectric strength | 1500VAC,1minute | |
Noise (1m) | ≤50dB | ||
Ambient temperature | -10ºC~+50ºC | ||
Humidity | 0~90%,No condensation | ||
Altitude | <2000m Higher than 2000m rated power should be reduced |
||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||
Equipped With Copper Transformer | Yes | ||
Solar Charger | Optional | ||
AC Charger | Optional | ||
Generator Port | Optional | ||
Size | 750*1500*1700 mm | ||
Weight | 620 kg |