Customization: | Available |
---|---|
Output Power: | >1000W |
Nature of Source Flow: | Passive inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | SHJ-NBQ7500-S48 | SHJ-NBQ7500-S96 | SHJ-NBQ7500-S110 | SHJ-NBQ7500-S220 | |
DC input |
Input rated voltage | 48 VDC | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 173.6A | 86.8A | 75.8A | 37.9A | |
Input DC voltage allowing range | 40-62 VDC | 80-124 VDC | 90-140 VDC | 180-280 VDC | |
AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |||
Input rated current | 68A / 62.5A / 34A /31A | ||||
Bypass transfer time | ≤40 ms (4ms optional) | ||||
AC output | Output rated power | 7.5KVA | |||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 68A / 62.5A / 34A / 31A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Wave | Pure sine wave (Isolation transformer) | ||||
THD. | ≤3%(Linear load) | ||||
Power factor (PF) | 0.8 | ||||
Overload capacity | 120%,10 minutes | ||||
Overcurrent capacity | 200%,10 seconds | ||||
Crest factor (CF) | 3:1 | ||||
Inverter efficiency | >90% | ||||
Working Environment |
Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -10ºC~+50ºC | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <2000m Higher than 2000m rated power should be reduced |
||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||||
Equipped With Copper Transformer | Yes | ||||
Solar Charger | Optional | ||||
AC Charger | Optional | ||||
Generator Port | Optional | ||||
Size | 560*780*950 mm | ||||
Weight | 110 kg |
Model | SHJ-NBQ10K-S48 | SHJ-NBQ10-S96 | SHJ-NBQ10-S110 | SHJ-NBQ10K-S220 | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 231.5 A | 115.7 A | 101A | 50.5 A | |
Input DC voltage allowing range | 40-62 VDC | 80-124 VDC | 90-140 VDC | 180-280 VDC | |
AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |||
Input rated current | 91A / 104A / 45.5 A / 42A | ||||
Bypass transfer time | ≤40 ms (4ms optional) | ||||
AC output | Output rated power | 10KVA | |||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 91A / 104A / 45.5 A /42A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Wave | Pure sine wave (Isolation transformer) | ||||
THD. | ≤3%(Linear load) | ||||
Power factor (PF) | 0.8 | ||||
Overload capacity | 120%,10 minutes | ||||
Overcurrent capacity | 200%,10 seconds | ||||
Crest factor (CF) | 3:1 | ||||
Inverter efficiency | >90% | ||||
Working Environment | Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -10ºC~+50ºC | ||||
Humidity | 0~90%,No condensation | ||||
Altitude | <2000m Higher than 2000m rated power should be reduced |
||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection | ||||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||||
Equipped With Copper Transformer | Yes | ||||
Solar Charger | Optional | ||||
AC Charger | Optional | ||||
Generator Port | Optional | ||||
Size | 520*780*950 mm | ||||
Weight | 110 kg |
Model | SHJ-NBQ15K-S48 | SHJ-NBQ15K-S96 | SHJ-NBQ15K-S110 | SHJ-NBQ15K-S220 | |
DC input | Input rated voltage | 48 VDC | 96 VDC | 110 VDC | 220 VDC |
Input rated current | 347 A | 173.6 A | 151 A | 75.8A | |
Input DC voltage allowing range | 40-62 VDC | 80-124 VDC | 90-140 VDC | 180-280 VDC | |
AC input (AC bypass) |
Allow input voltage range | 110 VAC / 120 VAC / 220 VAC / 240 VAC ± 15% | |||
Input rated current | 136A / 125A / 68A / 62.5A | ||||
Bypass transfer time | ≤40 ms (4ms optional) | ||||
AC output | Output rated power | 15KVA | |||
Output rated voltage and frequency | 110 VAC / 120 VAC / 220 VAC / 240 VAC,50Hz / 60Hz | ||||
Output rated current | 136A / 125A / 68A / 62.5A | ||||
Output voltage accuracy | 110 VAC / 120 VAC / 220 VAC / 240 VAC± 2% | ||||
Output frequency accuracy | 50Hz / 60Hz ± 0.05% | ||||
Wave | Pure sine wave (Isolation transformer) | ||||
THD. | ≤3%(Linear load) | ||||
Power factor (PF) | 0.8 | ||||
Overload capacity | 120%,10 minutes | ||||
Overcurrent capacity | 200%,10 seconds | ||||
Crest factor (CF) | 3:1 | ||||
Inverter efficiency | >90% | ||||
Working Environment | Dielectric strength | 1500VAC,1minute | |||
Noise (1m) | ≤50dB | ||||
Ambient temperature | -10ºC~+50ºC | ||||
Humidity | 0~90%, No condensation | ||||
Altitude | <2000m Higher than 2000m rated power should be reduced |
||||
Production function | Input reverse protection, input under-voltage protection, output overload protection, output short circuit protection, thermal protection |
||||
Communication interface | RS485/WIFI/GPRS/Ethernet (optional) | ||||
Equipped With Copper Transformer | Yes | ||||
Solar Charger | Optional | ||||
AC Charger | Optional | ||||
Generator Port | Optional | ||||
Size | 570*1020*1200 mm | ||||
Weight | 210 kg |