Customization: | Available |
---|---|
Output Power: | >1000W |
Nature of Source Flow: | Active Inverter |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
On grid wind turbine controller | SHJ-50K380 | SHJ-100K380 | SHJ-200K380 | ||||
Wind turbine input | |||||||
Power | 50KW | 100KW | 200KW | ||||
Max. Control power / current | 100KW/200A | 200KW/400A | 400KW/800A | ||||
Rated voltage of wind turbine (AC) | 380V/400V | 380V/400V | 380V/400V | ||||
Input voltage range | AC | 0-600V | 0-600V | 0-600V | |||
DC | 0-900V | 0-900V | 0-900V | ||||
Braking voltage (DC) | Default | 550V±1% | 550V±1% | 550V±1% | |||
Set range | 530-560V | 530-560V | 530-560V | ||||
Braking current (DC) | Default | 150A | 300A | 600A | |||
Set range | 0-150A | 0-300A | 0-600A | ||||
Braking time | Default | 10-20 min | |||||
Set range | 0-5000 min | ||||||
* Generator overspeed control | Default | >300 rpm/min | |||||
Set range | 0-1000 rpm/min | ||||||
* Over wind speed control | Default | 14 m/s | |||||
Set range | 0-45 m/s | ||||||
Manual control | Manual brake , *remote control brake (with communication function) | ||||||
Automatic control function | Dump load control, * yaw, * pitch, * mechanical brake, * hydraulic brake, * electromagnetic brake |
||||||
DC output parameters | |||||||
Output voltage range (DC) | 0-550V | 0-550V | 0-550V | ||||
Constant voltage (DC) | Default | 520V±1% | 520V±1% | 520V±1% | |||
Set range | 510-540V | 510-540V | 510-540V | ||||
Constant current (DC) | Default | 120A | 240A | 480A | |||
Set range | 0-120A | 0-240A | 0-480A | ||||
On grid wind turbine inverter | SHJ-50K | SHJ-100K | SHJ-200K | ||||
Rated output power (AC) | 50KW | 100KW | 200KW | ||||
Max. Output power (AC) | 55KW | 110KW | 220KW | ||||
Input voltage rang (DC) | 0-800V | 0-800V | 0-800V | ||||
MPPT Voltage range (DC)(DC) | 150V-700V | 150V-700V | 150V-700V | ||||
Max. Input current (DC) | 114.6A | 229A | 458.3A | ||||
Rated current | 104A | 208A | 416.7A | ||||
THD Current harmonic | <3%(at rated power) | ||||||
Power factor | >0.99 | ||||||
Max. efficiency | 96% | ||||||
Allowable grid voltage range (AC) | 220V/380V/440V/480V (Three-phase)±20% | ||||||
Allowable grid frequency range | 50Hz/60Hz±10% | ||||||
Automatic operation conditions | DC input and power grid meet the requirements, and the inverter operates automatically | ||||||
Restart time after power failure | 2min(Adjustable) | ||||||
General parameters | |||||||
Function | Rectification, DC output, output voltage control, output current control, Dump load control, control parameter setting, wind turbine curve setting | ||||||
Automatic protection | Control part: Over voltage protection, over current protection, reverse connection protection, lightning arrester Inverter part: Polarity reverse connection protection, short circuit protection, island effect protection, LVRT,overheat protection, overload protection, ground fault protection, etc |
||||||
Display | Touch screen, LCD | ||||||
Monitoring content | Wind turbine voltage, current, power, solar panel voltage, current, power, DC output voltage, current, power, inverter output power, * cumulative power generation, * power generation at any time, * rotational speed, * wind speed | ||||||
Protection level | IP20(Indoor)IP65 (Outdoors) | ||||||
Telematics | RS485/USB/GPRS/WIFI/Ethernet (optional) | ||||||
Environment | Operating amb. Temp. & Hum -30-60°C,<90% no condensation | ||||||
Noise (1m) | <40dB | ||||||
Refrigeration mode | Forced air cooling | ||||||
Controller size / weight | 500*500*900mm 56kg | 600*500*1200mm 107kg | 950*550*1700mm 150kg | ||||
Dump load size / weight | 920*770*380mm 80kg | 920*770*380mm*2 150kg | 923*739*510mm*4 280kg | ||||
Inverter size / weight | 750*600*1320mm 340kg | 1460*860*1820mm 1.4t | 1460*860*1820mm 1.6t | ||||